MQ SP4030 SAW • OPERATION MANUAL — REV. #0 (01/22/09) — PAGE 37
In case of an EMERGENCY, push the RED
EMERGENCY-STOP BUTTON to stop all
functions (Figure 31). Engine will not crank
when emergency stop button is depressed.
Figure 31. Emergency Stop Button
OPERATION
Stopping the Engine
1. When finished with the cut, move the control handle to
the NEUTRAL position.
2. Raise the saw blade out of the cut.
3. Reduce the throttle to idle.
4. Allow the engine to run one or two minutes to let the
engine cool down.
5. To stop the engine, turn the ignition switch to the OFF
position.
Restarting After Running Out of Fuel
The 2011 series Deutz engines do not require bleeding of
the fuel system if the engine is run out of fuel.
To restart the engine:
1. Refill the fuel tank with fresh, clean diesel fuel.
2. Re-prime the fuel system by squeezing the fuel prime
bulb (located inside the console, directly under the fuel
tank), until the fuel primer bulb becomes firm.
3. Crank the engine normally until it starts.
OPERATING SYNOPSIS
BEFORE STARTING — Check all fluid levels. Secure blade
firmly to blade shaft. Make sure all protective guards
are in place and properly mounted. Wear eye, ear
protection and protective clothing.
WATER SUPPLY Connect water supply to water inlet.
Move water ON/OFF CONTROL to ON position. Adjust
WATER FLOW CONTROL lever to desired position.
Drain watering system in cold weather to prevent
damage due to freezing.
BLADES Always follow blade manufacturer’s
recommendations for blade selection, speed and
application. NEVER exceed blade manufacturer’s
maximum rated RPM. See previous steps for
detailed blade mounting instructions.
STARTING ENGINE Set CONTROL HANDLE to
NEUTRAL position. Set THROTTLE to IDLE. Turn start
switch to ON position. Wait for glow plug indicator light
to go out. Momentarily turn switch to start position;
release switch as soon as engine starts. Allow engine
to warm up for several minutes before increasing
engine speed. Use approved diesel fuel only.
STOPPING ENGINE Do not stop engine abruptly when
hot! Reduce THROTTLE to IDLE and allow engine to
run 1 to 2 minutes before turning ignition switch off.
Damage to engine may occur if not allowed to cool
adequately.
FWD-NEUTRAL-REV CONTROL The panel mounted
handle controls FORWARD, NEUTRAL AND REVERSE
operation. Neutral position stops or holds saw in a
stationary position. Incremental movement in the
FORWARD or REVERSE direction will increase speed
proportionate to amount of movement.
RAISE-LOWER FUNCTION — RAISE-LOWER function is
controlled by the switch mounted at the right side of
the CONTROL HANDLE. Push toggle switch lever
forward to lower saw. Pull toggle switch lever backward
to raise saw.
BRAKES — This saw is equipped with parking brakes.
Brakes are applied automatically when engine is off
and disengaged when engine is running.